I biblioteket hittar du allt från applikationsnoter till skrivna artiklar. (Merparten är skrivet på engelska).

Använd sökfiltren för att bläddra för ett specifikt innehåll (t.ex. applikationsnoter) eller förfina din sökning till ett visst applikationsområde.

Om du vill se innehållet som vi har tillgängligt om ett visst ämne eller behöver hitta någon programvara, skriv bara in en sökning nedan. Observera att du måste skapa ett användarkonto för att få tillgång till vissa delar av innehållet. 

Filtrera efter typ av dokument
    Visar objekt (en) 1 - 10 av 242 Totalt
Case Study on IDAX300 and VAX020
The Power Grid Corporation of India Limited (PGCIL) is an Indian state-owned company headquartered in Gurugram (North India) engaged mainly in Trans-mission  of  Power  and  transmits  about  50%  of  the  total  power  generated  in  India  on  its  transmission  network.  The  company  owns  and  operates  about  1,61,790  circuit  kms  of  transmission  lines  at  800/765 kV,  400 kV,  220 kV  &  132 kV EHVAC and +500 kV HVDC levels and 248 sub-stations. Also, it has the transformation capacity of about 396 825 MVA as of 30th November 2019.
Publicerad 26 augusti 2020
Ladda ner PDF
TTRU3 Factory ratio testing of power transformer
Transformer equipment manufacturers (OEMs) have a critical need to measure true ratio, as they must confirm proper manufacture of their transformers during construction and final assembly. Improper construction has consequences of higher cost, late delivery, and poor quality. The ability of a ratio instrument to be used for all steps involved makes it a practical valueto OEMs because only one instrument is purchased and used throughout each stage. Only the most reliable and accurate instruments make it to the factory floor. Winding stack under constructionre used: Art Mandigo Winding Service.
Publicerad 3 augusti 2020
Ladda ner PDF
DLRO2: long test lead test mode
When measuring very low resistance the four-wire test method has for many years been the standard method. The main advantage being that it simply and easily removes the resistance of the test leads from the measurement. However, what happens when those test leads need to be verylong?
Publicerad 27 juli 2020
Ladda ner PDF
DLRO2: new difference meter
Introducing the first low resistance ohmmeter to feature a difference meter, a device that turns changes in resistance into a moving pointer and percentage change. When testing multiple similar connections, it makes it easy to spot those small increases in resistance that eventually turn into major faults.
Publicerad 27 juli 2020
Ladda ner PDF
DLRO2 safety warnings
Safety warnings for DLRO2
Publicerad 14 juli 2020
Ladda ner PDF
Transformer winding resistance measurement: field challenges
Megger’s article “Transformer Winding Resistance Measurement: Field Challenges” was presented at the 2020 NETA PowerTest Conference in Chicago, Il. This article takes an in-depth look at the lesser known facts associated with the DC winding resistance (WR) measurements, diving deeper into topics such as selection of the correct test current, and the importance of compliance voltage during the test. Phenomena as core saturation, current stabilization, the influence of winding inductance on readings, and the effect of temperature, are also explained.
Publicerad 12 juni 2020
Ladda ner PDF
Transformer turns ratio test: some unknown facts
Transformer Turns Ratio (TTR) is one of the most common test used to assess the condition of the transformer’s windings and core.  It is performed as a part of acceptance and maintenance test procedure to determine any problems due to poor design, assembly, handling, overloading, fault conditions or poor maintenance. TTR results are compared against the nameplate ratings to determine any possible insulation deterioration, shorted turns, core heating or any other winding or core abnormalities.TTR is a simple and easy test to perform that is often taken for granted without fully understanding the principle and basis of the test. In cases when measurements are not within expected limits, it becomes a challenging task to determine the root cause and resolve the problem. This paper will focus on some of the unknown facts associated with the TTR test. The paper covers in detail the effect of applied test voltage, comparative analysis of step up vs step down excitation, different vector configurations, differences between nameplate ratio, voltage ratio and turns ratio, sources of ratio and phase angle errors, comparison of per phase testing vs true three phase testing, extreme tap ratios being out of tolerance for On Load Tap Changers (OLTC), and TTR test correlation with other electrical tests. The paper also provides field test results and case examples to explain the above-mentioned unknown facts.
Publicerad 28 april 2020
Ladda ner PDF Läs hela artikeln
One touch OLTC with the TTRU3
Completing turns ratio tests on all transformer taps can be a cumbersome process. With One Touch OLTC from the TTRU3, anyone can configure and test all taps within a few short minutes.
Publicerad 22 april 2020
Ladda ner PDF
TTRU3 Calibration verification
When performing calibration verification of the TTRU3, the following factors need to be considered to achieve accurate measurements and prevent damage to your calibration fixture or TTRU3.
Publicerad 20 februari 2020
Ladda ner PDF
TDM45 series brochure
High power test and diagnostics combination for medium voltage cables.
Publicerad 28 november 2019
Ladda ner PDF
  • 1
  • 2
  • 3
  • 4